Mining Incidents

Laurel Alma Coal

Elk Run Coal Company Inc · Underground
Dorothy, Boone County, WV  ·  Abandoned
MSHA Mine ID: 4608457

Laurel Alma has $38K in proposed MSHA penalties and $0 outstanding across 3 contested dockets, plus health sampling and the full incident record.

Watch this mine

Email me when a new MSHA incident is filed at Laurel Alma.

Fatalities
0
Total incidents
61
Years on record
1996–2002
Latest incident
Dec 2002
Compliance record
MSHA citations since 2000
174
citations
89
significant & substantial
$38,113
proposed penalties
$33,901
paid to date
89% of proposed penalties paid to date, a $4,212 gap.
Source: MSHA violations data, updated weekly.
Inspection activity
MSHA inspections since 2000
59
inspections on record
2,221
inspection hours
7.8
citations per 100 inspection hours
This rate is recorded citations divided by MSHA inspection hours, per 100 hours. It reflects inspection effort, not mine size or production.
174 citations across 2,221 inspection hours.
Source: MSHA inspections data, updated weekly.

Laurel Alma has $38K in proposed MSHA penalties and $0 outstanding across 3 contested dockets.

Penalty disposition
Differences between proposed and paid penalties reflect both settlements and conference reductions and amounts still owed. Outstanding is the balance currently owed.
$38K
proposed penalties
$34K
current assessed
$34K
paid to date
$0
outstanding
167 assessments are final orders; 3 contested dockets.
As of the most recent assessment on 2003-05-30.
Source: MSHA assessed-violations and conference/litigation data, updated weekly.

MSHA sampling at Laurel Alma shows respirable coal dust averaging 1.00 mg/m3 (79% compliant) across 253 samples.

Health sampling
A sample is a point in time compliance measurement, not an individual exposure history. These figures describe MSHA sampling records and do not establish causation or personal dose.
Respirable coal dust
Respirable coal dust and silica figures cover coal facilities. Dust compliance is measured against the current 1.5 mg/m3 standard; samples predating the 2014 standard are included, so compliance rates are a coarse historical signal.
1.00
dust avg (mg/m3)
6.22
dust max (mg/m3)
79%
within 1.5 mg/m3
253
samples
Most recent sample: 2002-12-12.
Silica (quartz)
6.6
silica avg (%)
11.8
silica max (%)
19
samples
Most recent sample: 2002-12-10.
Noise
40%
over PEL
5
samples
Most recent sample: 2000-03-22.
Source: MSHA respirable dust, quartz, and noise sampling records, updated weekly.
Quarterly safety rates
Citations per million reported employee-hours. Rates begin in 2000, when MSHA's quarterly employment data starts; earlier incidents are counted but cannot be rate-adjusted. Quarters under 100,000 reported hours are greyed: too few hours for a stable rate.
Citations per million employee-hours, as reported to MSHA
Quarter Hours worked Citations S&S Per 1M hrs
2003 Q4 0 0 0
2003 Q3 4 0 0 0.0
2003 Q2 0 1 0
2003 Q1 428 4 2 9345.8
2002 Q4 24,467 7 3 286.1
2002 Q3 25,732 17 12 660.7
2002 Q2 27,411 8 5 291.9
2002 Q1 19,852 17 13 856.3
Show 8 earlier quarters
Quarter Hours worked Citations S&S Per 1M hrs
2001 Q4 21,128 22 11 1041.3
2001 Q3 15,517 27 14 1740.0
2001 Q2 18,360 18 8 980.4
2001 Q1 14,788 16 8 1082.0
2000 Q4 15,730 5 3 317.9
2000 Q3 17,026 19 7 1115.9
2000 Q2 13,921 7 1 502.8
2000 Q1 14,966 6 2 400.9
No fatalities recorded at this mine.

Reportable incidents

61 on file

2002 · 13 incidents

December 21, 2002 WV · Coal FALL OF ROOF OR BACK
Elk Run Coal Company Inc · Accident type, without injuries

AN UNPLANNED ROOF FALL WAS DISCOVERED IN THE #6 ENTRY NEAR SPAD 4257. ALL APPROACHES WERE TIMBERED OFF. THE AREA WILL NOT BE REHABILITATED.

November 19, 2002 WV · Coal roof bolter, rock bolter, pinner, mobile roof support operator (mrs) MACHINERY
Elk Run Coal Company Inc · Struck by falling object

EE WAS OPERATING A ROOF BOLTER IN THE CROSSCUT BETWEEN THE #5 & #6 ENTRY ON THE HELPER SIDE. HISDRILL BECAME LODGED WHILE DRILLING THE TOP. WHILE RETRIEVING THE DRILL STEEL, A PIECE OF ROCK ME ASURING 12"X 12"X 12" FELL STRIKING HIM ON RIGHTHAND, LITTLE FINGER.

November 19, 2002 WV · Coal FALL OF ROOF OR BACK
Elk Run Coal Company Inc · Accident type, without injuries

A ROOF FALL WAS DISCOVERED IN THE #8 ENTRY, NEARSPAD 4640, @3000'FROM THE ACTIVE FACE. THE DIMENSIONS ARE 40'L X 20'W X 4'H. THE AREA HAS BEEN BREAKERED OFF AND WILL NOT BE REHABILITATED.

November 4, 2002 WV · Coal laborer, bull gang, faceman, parts runner, roustabout, roof trimmer/scaler HANDLING OF MATERIALS
Elk Run Coal Company Inc · Over-exertion in lifting objects

EE WAS INSTALLING A 48"BOTTOM BELT ROLLER, 1 BRK. OUTBY THE SECTION FEEDER. WHEN HE BENT OVER & PICKED UP THE ROLLER & TURNED TOWARD THE BELT STRUCTURE TO INSTALL THE ROLLER, HE FELT SOMETHING "POP" IN HIS BACK.

October 16, 2002 WV · Coal FALL OF ROOF OR BACK
Elk Run Coal Company Inc · Accident type, without injuries

AN UNINTENTIONAL ROOF FALL OCCURRED IN THE #4 ENTRY OLD TRACK ENTRY OF OLD WORKS, 3000' FROM THE ACTIVE FACE. THE FALL MEASURED APPROX. 30' LONG X 20' WIDE X 4' HIGH. THE ENTRANCES TO THE FALL HAVE BEEN BREAKERED OFF AND WILL NOT BE REHABILITATED.

September 23, 2002 WV · Coal FALL OF ROOF OR BACK
Elk Run Coal Company Inc · Accident type, without injuries

AN UNINTENTIONAL ROOF FALL OCCURED APPROX. 3000'FROM THE ACTIVE FACE IN THE #5 ENTRY OF AN OLD WORKS SECTION. ALL ENTRANCES TO THE FALL HAVE BEEN BREAKERED OFF. THIS FALL WILL NOT BE REHABILI TATED. THE FALL MEASURED 20'L X 20'W X 4'H.

September 18, 2002 WV · Coal FALL OF ROOF OR BACK
Elk Run Coal Company Inc · Accident type, without injuries

AN UNINTENTIONAL ROOF FALL OCCURRED IN THE #6 BREAK IN THE TRACK ENTRY APPROXIMATELY 800 FT. FROM THE ACTIVE FACE. THE FALL MEASURED 25' L X 20' W X 4' H. ALL ENTRANCES TO THE FALL WERE BREAKE RED OFF AND THE FALL WILL BE REHABILITATED.

August 9, 2002 WV · Coal FALL OF ROOF OR BACK
Elk Run Coal Company Inc · Accident type, without injuries

AN UNINTENTIONAL ROOF FALL OCCURRED IN THE #2 ENTRY NEAR #29 BREAK IN RETURN. APPROX. 2,210 FT. AWAY FROM ACTIVE FACE. FALL MEASURED 35'L X 20'W X 4'H. VENTILATION WAS NOT AFFECTED. ALL ENTRAN CES TO FALL ARE BREAKERED OFF. WILL NOT BE REHABILITATED.

August 5, 2002 WV · Coal FALL OF ROOF OR BACK
Elk Run Coal Company Inc · Accident type, without injuries

AN UNINTENTIONAL ROOF FALL OCCURRED IN OLD WORKS AREA IN RETURN ENTRY AT #21 BREAK. 1,860 FEET FROM ACTIVE FACE. THE FALL MEASURED 35'L X 20'W X 4 1/2' H. ALL ENTRANCES TO THE FALL HAVE BEEN B REAKERED OFF. THIS AREA WILL NOT BE REHABILITATED. FALL WAS INVESTIGATED BY MSHA INSPECTOR.

August 4, 2002 WV · Coal section foreman, bullgang foreman, labor foreman, leadman, shift boss SLIP OR FALL OF PERSON
Elk Run Coal Company Inc · Fall onto or against objects

EE ARRIVED AT THE MINE SITE PRIOR TO HIS SHIFT & PARKED HIS TRUCK. HE PROCEEDED TO THE BACK OF HIS TRUCK TO GET HIS WORK CLOTHES. AT THIS POINT A RATTLESNAKE STARTLED HIM CAUSING HIM TO JUMP B ACKWARDS & FALL INTO A STACK OF METAL TRUCK TIES INJURING HIS BACK.

March 25, 2002 WV · Coal apprentice, trainee MACHINERY
Elk Run Coal Company Inc · Struck by... (Not Elsewhere Classified)

EE WAS PUTTING UP A BOLT, WHEN THE BOLT BENT. ASHE REACHED OUT TO GRAB THE BOLT HE ACCIDENTLY ENGAGED THE ROTATION OF THE DRILL CHUCK CAUSING THE BOLT TO SPIN AND STRIKE HIM ON THE WRIST.

February 8, 2002 WV · Coal shuttle car operator, mantrip operator, ramcar operator, rail runner, buggy operator DISORDERS (REPEATED TRAUMA)
Elk Run Coal Company Inc · Over-exertion (Not Elsewhere Classified)

WORKING IN AND AROUND COAL MINES FOR 33 YEARS. EE EXPERIENCED PAIN IN HIS RT. SHOULDER AND WAS DIAGNOSED WITH SUBCROMIAL BURSITUS ON 2/17/02.

January 18, 2002 WV · Coal laborer, bull gang, faceman, parts runner, roustabout, roof trimmer/scaler HANDLING OF MATERIALS
Elk Run Coal Company Inc · Struck by flying object

EE WAS BENIDNG OVER TO PICK UP HIS DINNER BUCKET WHEN HE STEPPED ON THE SIDE OF A HIGH-LIFT JACK. THE JACK HANDLE FLEW UP STRIKING EE ON THE LEFT SIDE OF UPPER LIP, CAUSING LACERATION.

2001 · 9 incidents

November 16, 2001 WV · Coal supply man, supply worker, nipper SLIP OR FALL OF PERSON
Elk Run Coal Company Inc · Fall from machine

OPERATING THE UNDERGROUND FORKLIFT FROM A POSITION HALF IN AND HALF OUT (DUE TO HIS SIZE) WHILE UNLOADING SUPPLIES THE OPERATOR'S SIDE REAR TIRES FELL OFF CAUSING HIM TO BE THROWN TO THE GROUN D.

October 27, 2001 WV · Coal laborer, bull gang, faceman, parts runner, roustabout, roof trimmer/scaler HANDTOOLS (NONPOWERED)
Elk Run Coal Company Inc · Struck by... (Not Elsewhere Classified)

EMPLOYEE WAS IN THE PROCESS OF CLAMPING OFF THE #3 BELT LINE. AS HE AND A CO-WORKER TRIED TO GETTHE CLAMPS TOGETHER BY PUSHING THEM TOGETHER W/ A SLATE BAR, THE BAR SLIPPED CAUSING THE CLAMPS AND BAR TO STRIKE EMPLOYEE ON THE RIGHT WRIST.

October 15, 2001 WV · Coal laborer, bull gang, faceman, parts runner, roustabout, roof trimmer/scaler HANDLING OF MATERIALS
Elk Run Coal Company Inc · Struck by... (Not Elsewhere Classified)

EE WAS CARRYING A CAN OF HYDRAULIC OIL TO THE SECTION SCOOP. WHEN HE ARRIVED AT THE SCOOP HE DROPPED THE CAN OF OIL WHICH IN TURN LANDED ON HIS LEFT HAND. THE BOTTOM OF THE OIL CAN CUT HIS LEF T THUMB REQUIRING SIX SUTURES. DEGREE 6 CLASS 9 ACCIDENT.

October 10, 2001 WV · Coal front-end loader, scraper-loader operator, pan operator, payloader, scraper rig operator POWERED HAULAGE
Elk Run Coal Company Inc · Struck by... (Not Elsewhere Classified)

EE WAS OPERATING LOADER IN STOCKPILE. HE WAS LOADING COAL OUT AT TOE OF PILE WHEN STOCKPILE COLLAPSED COVERING FRONT AND SIDES OF LOADER. COAL KNOCKED OUT FRONT WINDSHIELD, COVERING HIM UP FRO N CHEST DOWN. INJURIES WERE CUTS AND BRUISES TO FACE AND BODY.

October 4, 2001 WV · Coal roof bolter, rock bolter, pinner, mobile roof support operator (mrs) MACHINERY
Elk Run Coal Company Inc · Struck by falling object

EE WAS BOLTING TOP IN #9 ENTRY 3 BREAKS INBY SPAD 4073 WHEN DRILL STEEL CAME IN CONTACT WITH THETOP. A PIECE OF ROCK MEASURING 9" THICK, 3' WIDEFEATHERING DOWN TO 0" AND 15" IN LENGHT FELL ON HIS LEFT HAND STRIKING AGAINST THE DRILLPOT.

August 31, 2001 WV · Coal FALL OF ROOF OR BACK
Elk Run Coal Company Inc · Accident type, without injuries

AN UNINTENTIONAL ROOF FALL OCCURRED IN THE FACE OF THE #4 ENTRY. THE FALL MEASURED 60' L X 20' WX 5-6' H. ALL AREAS TO THE FALL HAVE BEEN BREAKERED OFF. THE FALL AREA WILL NOT BE REHABILITATED

August 25, 2001 WV · Coal FALL OF ROOF OR BACK
Elk Run Coal Company Inc · Accident type, without injuries

AN UNINTENTIONAL ROOF FALL OCCURRED IN THE #8 ENTRY NEAR SPAD #344. APPROX. 70' OUTBY THE FACE. THE FALL MEAUSRED 70' LONG 20' WIDE AND 6' HIGH. ALL AREAS TO THE FALL HAVE BEEN BREAKERED OFF. THIS AREA WILL NOT BE REHABILITATED.

June 5, 2001 WV · Coal mine manager, mine foreman, mine owner HANDTOOLS (NONPOWERED)
Elk Run Coal Company Inc · Struck by... (Not Elsewhere Classified)

THE INJURED WAS MAKING A SHUTTLE CAR SPLICE, AS HE WAS USING THE SPLICING TOOL, A PIECE OF METAL SHEARED OFF AND PENETRATED HIS LEFT HAND, WHICH REQUIRED ONE SUTURE AFTER A PHYSICIAN TRIED TO REMOVE THE METAL.

April 9, 2001 WV · Coal FALL OF ROOF OR BACK
Elk Run Coal Company Inc · Accident type, without injuries

AN UNINTENTIONAL ROOF FALL WAS DISCOVERED ON 4-9-01 IN THE #9 RETURN ENTRY. THE FALL MEASURED APPROX 40 FT LENGTH 20 FT WIDE, 4 1/2 FT HIGH. THE AREA AROUND THE FALL WAS BREAKERED OFF, VENTILA TION WAS NOT AFFECTED. THE AREA WILL NOT BE REHABILITATED. (5600 FT FROM THE WORKING FACE)

2000 · 7 incidents

December 13, 2000 WV · Coal continuous miner operator, coal mole operator MACHINERY
Elk Run Coal Company Inc · Caught in, under or between a moving and a stationary object

INJURED WAS IN THE PROCESS OF RESPOSISTIONING THE MINER AND CAUGHT HIMSELF BETWEEN. THE COAL RIB AND THE TURNTABLE OF THE CONTINUOUS MINER BOOM.

December 2, 2000 WV · Coal laborer, bull gang, faceman, parts runner, roustabout, roof trimmer/scaler SLIP OR FALL OF PERSON
Elk Run Coal Company Inc · Struck by flying object

EE WAS HELPING MOVE THE WATER LINE UP BY USING ASCOOP TO PULL IT HE WAS STANDING TO THE SIDE WHILE THE FOREMAN PULLED THE WATER LINE. THE WATERLINE CAUGHT ON A ROCK CAUSING IT TO FLIP UP CATCH ING HIM IN THE STOMACH WHICH MADE HIM FALL BACK WARD TO THE MINE FLOOR

October 20, 2000 WV · Coal laborer, bull gang, faceman, parts runner, roustabout, roof trimmer/scaler SLIP OR FALL OF PERSON
Elk Run Coal Company Inc · Fall onto or against objects

EMPLOYEE WAS ATTEMPTING TO HOOK A CHAIN TO THE SCOOP BUCKET IN ORDER TO PULL THE BELT. WHEN HE STEPPED INTO THE BUCKET HE SLIPPED ON LOOSE COALAND FELL BACKWARD INTO THE SCOOP BUCKET.

August 28, 2000 WV · Coal FALL OF ROOF OR BACK
Elk Run Coal Company Inc · Accident type, without injuries

AN UNINTENTIONAL ROOF FALL WAS DISCOVERED IN THE#8 ENTRY AT SPAD #3574 ABOUT 3000' FROM THE FACEMEASURING 20'LONG X 20'WIDE X 5'HIGH.

August 20, 2000 WV · Coal FALL OF ROOF OR BACK
Elk Run Coal Company Inc · Accident type, without injuries

AN UNINTENTIONAL ROOF FALL WAS DISCOVERED ON 8-20-00. THE FALL MEASURED 80' BY 20' BY 6' AND WAS LOCATED IN THE #7 ENTRY AT SPAD 3673. THIS AREA IS 1200' FROM THE FACE. THIS AREA WILL NOT BE REHABILITATED.

May 3, 2000 WV · Coal mine manager, mine foreman, mine owner ALL OTHER OCCUPATIONAL ILLNESSES
Elk Run Coal Company Inc · (Not Elsewhere Classified)

WORKING IN AND AROUND COAL MINES FOR 32 YRS. HEWAS FIRST DIAGNOSED WITH COMPRESSED DISCS IN HISSPINE 5/3/00. THIS WAS BROUGHT TO MY ATTENTION ON 5/12/00.

March 3, 2000 WV · Coal FALL OF ROOF OR BACK
Elk Run Coal Company Inc · Accident type, without injuries

AN UNINTENTIONAL ROOF FALL WAS DISCOVERED WHILE TRAVELING THE RETURN AIRWAY. THE FALL MEASURED 10'LONG, 18'WIDE, 6'HIGH. ALL ENTRANCES TO THIS AREA HAVE BEEN BREAKERED OFF. THE FALL OCCURRED A T SURVY STATION 024 APPROX 4000' FROM ACTIVE SECTION.

1999 · 7 incidents

November 15, 1999 WV · Coal FALL OF ROOF OR BACK
Elk Run Coal Company Inc · Accident type, without injuries

AN UNINTENTIONAL ROOF FALL OCCURED MEASURING 60'L X 20'W X 4-6'H WAS DISCOVERED IN RETURN AIRWAYWHILE PERFORMING WEEKLY EXAMINATION. ALL ENTRANCES HAVE BEEN SUPPORTED BY R. COZART OF WVMHST IN SPECTOR.

September 8, 1999 WV · Coal belt foreman, maintenance foreman, maintenance supervisor HANDLING OF MATERIALS
Elk Run Coal Company Inc · Over-exertion in lifting objects

INJURED WAS CHANGING A SHUTTLE CAR TIRE WHEN HE FELT A PAIN IN HIS LOWER BACK.

May 25, 1999 WV · Coal FALL OF ROOF OR BACK
Elk Run Coal Company Inc · Accident type, without injuries

AN UNINTENTIONAL ROOF FALL OCCURRED IN THE INTAKE AIRWAY AND WAS DISCOVERED WHILE MAKING A WEEKLY EXAMINATION. THE FALL IS LOCATED 80 FT IN BY SURVEY 3207 AND MEASURED 100' LONG BY 19' WIDE BY 5' HIGH. ALL ENTRANCES HAVE BEEN TIMBERED OFF.

May 6, 1999 WV · Coal FALL OF ROOF OR BACK
Elk Run Coal Company Inc · Accident type, without injuries

AN UNINTENTIONAL ROOF FALL OCCURRED IN THE #8 (RETURN) ENTRY AT SURVEY STATION #526. THE VENTILATION CONTROL AFFECTING THIS AREA WILL BE MOVEDFOR VENTILATION PURPOSES. THIS AREA IS APPROX 3800 FT FROM ACTIVE FACE T

May 4, 1999 WV · Coal FALL OF ROOF OR BACK
Elk Run Coal Company Inc · Accident type, without injuries

AN UNINTENTIONAL ROOF FALL OCCURRED 1200'FT FROMAN ACTIVE WORKINGS IN THE #3 NEUTRAL ENTRY. THE FALL MEASURED 40'LX 20'W X 41/2'THICK. FALL WAS INVESTIGATED BY MSHA INSPECTOR. AREA WILL NOT BE REHABILITATED. ALL ENTRANCIES TIMBERED OFF

February 26, 1999 WV · Coal FALL OF ROOF OR BACK
Elk Run Coal Company Inc · Accident type, without injuries

A FALL, 20' X 20' X 6 1/2', OCCURRED IN #2 ENTRY AT SURVEY STATION 3208. AREA CONCERNED WAS IN RETURN AIRWAY AND WAS TIMBERED AND CRIBBED OFF. THIS AREA WILL NOT BE REHABILITATED. ALL ENTRANCE S BLOCKED OFF BY CRIBS & TIMBERS.

January 4, 1999 WV · Coal FALL OF ROOF OR BACK
Elk Run Coal Company Inc · Accident type, without injuries

A ROOF FALL WAS DISCOVERED DURING A WEEKLY EXAM OF THE RETURN AIRWAY 1 X OUTBY SPAD 300 IN #2 ENTRY APPROX 7500 FT FROM ACTIVE FACE AREA. FALL MEAS 20'WIDE X 20'LONG X 4'THICK.

1998 · 6 incidents

October 24, 1998 WV · Coal roof bolter, rock bolter, pinner, mobile roof support operator (mrs) POWERED HAULAGE
Elk Run Coal Company Inc · Over-exertion (Not Elsewhere Classified)

EE STEPPED ON A SHUTTLE CAR CABLE AT APPROX THE SAME TIME THE S/C OPERATOR STARTED THE S/C. HE WAS APPROX 10' FROM THE ANCHOR POINT WHEN S/C WAS STARTED. THIS RESULTED IN A SPRAIN TO RT KNEE.

October 15, 1998 WV · Coal FALL OF ROOF OR BACK
Elk Run Coal Company Inc · Accident type, without injuries

A ROOF FALL WAS DISCOVERED 18'LX20'WX41/2' THICKWHILE A WEEKLY EXAMINATION OF A RETURN AIRWAY 1 CROSSCUT INBY SURVEY STATION OF 2669. CO OFFICIAL MIKE HENDRIX WAS TRAVELING MSHA INSP RICHARD STEVENS Y

September 30, 1998 WV · Coal scoop car operator ALL OTHER OCCUPATIONAL ILLNESSES
Elk Run Coal Company Inc · (Not Elsewhere Classified)

EE COMPLAINED ON BEING SICK AND THROWN UP ASKED TO GO TO DR WENT TO ER WAS TOLD HE HAD EQUILIBRIUM PROBLEM HAD APPT WITH SPECIALIST ON 10-13-98 WORKED UNTIL THEN ON. DR TOLD HIM TO STAY OFF CO UPLE WEEKS. HE COULD NOT REMEMBER DRIVING TO WORK THAT DAY.

August 10, 1998 WV · Coal FALL OF ROOF OR BACK
Elk Run Coal Company Inc · Accident type, without injuries

AN UNINTENTIONAL ROOF FALL WAS DISCOVERED 2X INBY SPAD 997 DURING A WEEKLY EXAM BY THGE MINE FOREMAN WHOW AS ACCOMPANIED BY MSHA INSPECTOR. FALL WAS IN #8 ENTRY (RETURN) 3000' FROM ACTIVE FACE .

July 15, 1998 WV · Coal FALL OF ROOF OR BACK
Elk Run Coal Company Inc · Accident type, without injuries

XCUT FROM #4 TO #5 ENTRIES AT SPAD #2666. THIS AREA CONSISTED OF SANDY SHALE AND LAMINATED. AREA HAD LOW COVER ANDF WHEN XCUTS WERE DEVELOPED AREA TOOK ADDED WEIGHT.

April 23, 1998 WV · Coal roof bolter, rock bolter, pinner, mobile roof support operator (mrs) SLIP OR FALL OF PERSON
Elk Run Coal Company Inc · Caught in, under or between (Not Elsewhere Classified)

EE WAS LOADING A SECTION OF A 4" ALUMINUM WATERLINE ONTO A FLAT BED RAIL CAR. ATER LOADING THIS SECTION EE NOTICED A COWORKER CLOSE BEHIND AS HETRIED TO MOVE CLEAR, HIS LEFT FOOT CAUGHT UNDER A PIECE OF ROCK HE FEL INTO A TWISTING MOTION U INJURED HIS LEFT KNEE

1997 · 10 incidents

October 29, 1997 WV · Coal shuttle car operator, mantrip operator, ramcar operator, rail runner, buggy operator DISORDERS (REPEATED TRAUMA)
Elk Run Coal Company Inc · (Not Elsewhere Classified)

GPF-WORKING IN AND AROUND COAL MINES FOR APPROXIMATELY 14 YEARS. THE EMPLOYEE WAS OFFICIALLY DIAGNOSED AS HAVING CARPAL TUNNEL ON 10-29-97. IT WAS BROUGHT TO MY ATTENTION ON 12-22-97.

September 11, 1997 WV · Coal FALL OF ROOF OR BACK
Elk Run Coal Company Inc · Accident type, without injuries

ON 9-11-97 DURING WEEKLY EXAM OF THE RETURN AIRWAY THE FALL WAS FOUND. LOCATED IN 3 ENTRY 3560 FT OUTBY THE FACE 1 BREAK INBY SPAD 1975.

May 7, 1997 WV · Coal FALL OF ROOF OR BACK
Elk Run Coal Company Inc · Accident type, without injuries

A ROOF FALL OCCURRED IN THE #7 INTAKE ENTRY APPROX 220 FT WITH THE FACE NEAR SS#1796. THE VENTILATION OVER THE PASSAGE OF PERSONS WAS AFFECTED. THE AREA WILL NOT BE REHABILATED. THE SIZE O F THE FALL WAS 70'L,X 20'W, X 48" THICK

May 4, 1997 WV · Coal FALL OF ROOF OR BACK
Elk Run Coal Company Inc · Accident type, without injuries

YA ROOF FALL OCCURED IN THE MAINS #8 ENTRY APPROX 40' OUTBY FACE AT SPAD 1795. THE FALL WAS APPROX 100'X20'X5 1/2'. VENTILATION OR PASSAGE OF MEN WAS NOT EFFECTED. THE AREA WILL NOT BE REHA BILITATED.

April 28, 1997 WV · Coal FALL OF ROOF OR BACK
Elk Run Coal Company Inc · Accident type, without injuries

A ROOF FALL MEASURED IN THE MAIN #6 ENTRY APPROX. 3000' OUTBY THE ? NEAR 55 #1626. THE SIZE OF THE FALL WAS 100' LONG X 20' WIDTH X 6' HIGH. THE VENTILATION NOR THE PASSAGE OF PERSONS WAS AFFE CTED. THE AREA WILL NOT BE REHABILTITATED.

April 18, 1997 WV · Coal haul/off road/coal/ore/pit/quarry/rock/rubber tire truck driver, transportation truck driver HANDLING OF MATERIALS
Elk Run Coal Company Inc · Caught in, under or between (Not Elsewhere Classified)

EE WAS DRIVING COAL TRUCK WHEN TAILGATE PROPPED OPEN. HE LIFTED TAILGATE WITH ONE HAND TRIED TO CLEAN COAL OFF WITH OTHER HAND. TAILGATE WAS TOO HEAVY TO HOLD, SLAMMED SHUT ON MIDDLE FINGER.

March 12, 1997 WV · Coal FALL OF ROOF OR BACK
Elk Run Coal Company Inc · Accident type, without injuries

THE FALL OCCURRED IN #7 ENTRY, RETURN NEAR SS#1622. THE SIZE OF THE FALL WAS 60' LONG X 20' WIDE X 5' HIGH. VENTILATION & PASSAGE OF PERSONS WAS NOT AFFECTED. THE AREA WILL NOT BE REHAVILITATE D. THIS OCCURRED 400' FROM THE FACE AREA.

March 8, 1997 WV · Coal FALL OF ROOF OR BACK
Elk Run Coal Company Inc · Accident type, without injuries

A ROOF FALL OCCURRED IN THE #6 INTAKE ENTRY APPROX 100' FROM THE (----?----), NEAR SURVEY STATION #1630. THE SIZE OF THE FALL WAS 20' LONG X 25' WIDE X 6' HIGH. NO VENTILATION OR PASSAGE OF PE RSONS WAS AFFECTED. THE AREA WILL NOT BE REHABILATATED.

March 8, 1997 WV · Coal FALL OF ROOF OR BACK
Elk Run Coal Company Inc · Accident type, without injuries

A ROOF FALL OCCURRED IN THE #6 ENTRY APPROXIMATELY 100'FROM THE BACK ACCESS STATION #1630. THE SIXE OF THE FALL WAS 20' LONG BY 25 WIDE 6' HIGH .NO VENTALATION OR PASSAGES OF PERSONS WAS AFFEC TED. THE AREA WILL NOT BE REHABILITATED.

February 9, 1997 WV · Coal FALL OF ROOF OR BACK
Elk Run Coal Company Inc · Accident type, without injuries

ON 2-9-97 A ROOF FALL WAS FOUND IN THE #9 RETURNENTRY NEAR SS #0482 APPROX. 3000 FEET FROM THE FACE AREAS. THE SIZE OF THE FALL WAS 110' LONG X 20' WIDE X 60' HIGH. 4' RESIN BOLTS HAD BEEN INS TALLED FOR PERMANENT SUPPORT AND WOODEN CRIBS SET FOR ADDITIONAL SUPPORT. THE PASSAGE OF PERSONSAND VENTILATION WAS NOT AFFECTED. THE AREA WILL NOT BE REHABILITATED.

1996 · 9 incidents

December 5, 1996 WV · Coal continuous miner operator, coal mole operator FALL OF ROOF OR BACK
Elk Run Coal Company Inc · Struck by falling object

THE EE WAS OPERATING A REMOTE CONTROL CONTINTUOUS MINTER WHEN A SMALL PIECE OF ROCK FELL FROM THE ROOF. THE ROCK MEASURING 2'X2'X1' THICK CONTATCTED THE TOP OF HIS RIGHT FOOT CAUSING A MINOR F FRACTURE TO A SMALL METATARSAL BONE

November 7, 1996 WV · Coal beltman, conveyor man, conveyor belt worker, mobile bridge carrierman, feeder operator, conveyor rider DUST DISEASE OF LUNGS
Elk Run Coal Company Inc · Inhalation of radiations, caustics, toxic and noxious substances

THE EE WAS DIAGNOSED AS HAVING A MINOR CONDITION OF PNEUMOCONIOSIS. HE HAS WORKED AROUND COAL MINES FOR 18 YEARS.

November 6, 1996 WV · Coal FALL OF ROOF OR BACK
Elk Run Coal Company Inc · Accident type, without injuries

A ROOF FALL OCCURRED IN THE #2 LEFT RETURN ENTRY APPROX. 900' FROM THE FACE NEAR SS#1366. THE SIZE OF THE FALL WAS 35' LONG X 20' WIDE X 54" HIGH. THE VENTILATION AND PASSAGE OF MEN WERE NOT A FFECTED.

November 6, 1996 WV · Coal FALL OF ROOF OR BACK
Elk Run Coal Company Inc · Accident type, without injuries

A ROOF FALL OCCURRED IN THE #6 INTAKE ENTRY APPROX. 1300' FROM THE FACE NEAR SS# 1327. THE SIZE OF THE FALL WAS 25' LONG X 20' WIDE X 4' HIGH.

September 9, 1996 WV · Coal beltman, conveyor man, conveyor belt worker, mobile bridge carrierman, feeder operator, conveyor rider POWERED HAULAGE
Elk Run Coal Company Inc · Struck by... (Not Elsewhere Classified)

EE WAS A PASSENGER IN A GOODMAN 10 TON LOCOMOTIVE PUSHING A SUPPLY CAR OF TIMBERS TO THE WORKING SECTION. ONE OF THE TIMBERS CONTACTED THE MINE ROOF AND WAS PUSHED INTO THE PASSENGER COMPARTME NT. THE TIMBER CONTACTED THE INJURED'S RIGHT ARM CAUSING A FRACTURE.

August 8, 1996 WV · Coal FALL OF ROOF OR BACK
Elk Run Coal Company Inc · Accident type, without injuries

A ROOF OCCURED IN THE 3 NENTUAL ENTRY 35 128, APPROX. ROOF FROM THE FUSES THE SIGN OF THE FALL WAS 25'LONG X 20' WIDE X 4' THICK THIS AREA HAD BEEN PERMANETLY SUPPORTED BY 42' RESIN CORRECTED ROOF BOLTS. THE VENTILATION HAD PASSAGE OF PERSON WAS NOT AFFECTED. THE RESIN WILL NOT BE REHABLIATED.

August 8, 1996 WV · Coal FALL OF ROOF OR BACK
Elk Run Coal Company Inc · Accident type, without injuries

A ROOF FALL OCCURRED WAS THE 8 RETURN ENTRY ONE CURRENT OUTBY 55 1141 APPROX. 600 FT FROM THE FACES. THE SIZE OF THE FALL LINER 20' LONG X 20' WIDE X 4' THICK. THES AREA HARD BEEN PERSONNELTLY SUPPORT WITH 42" RESIN GROUTED ROOF BOLTS THE VENTILATION AND PASSAGE OF PERSONS WAS NOT AFFECTED. THE LEASE WILL NOT REHABILITATES.

April 3, 1996 WV · Coal FALL OF ROOF OR BACK
Elk Run Coal Company Inc · Accident type, without injuries

A ROOF FALL OCCURRED IN THE #2 RETURN ENTRY NEAR SS#553 APPROX 3000' OUTBY THA FACE. THE FALL MEASURED 40' LONG X 18' WIDE X 4' PLUS THICK. THE AREA HAD BEEN PERMANENTLY SUPPORTED WITH 4' RESI N ROOF BOLTS & WOODEN CRIBS. THE FALL DID NOT AFFECT PASSAGE OF PERSONS OR VENTILATION. THE AREA WILL BE REHABILITATED.

January 19, 1996 WV · Coal FALL OF ROOF OR BACK
Elk Run Coal Company Inc · Accident type, without injuries

A ROOF FALL EXCURRED IN THE FACE OF 6 ENTRY. THE FALL MEASURED 15' LONG X 18' WIDE X 15' THICK. THE AREA WAS SUPPORTED WITH 4' RESIN GERONTED BOLTS. THIS AREA WAS 1" CROSSCUT INBY SS 0546. THE AREA WILL NOT BE REHABILITATES.