DRIVER WAS HAULING A LOAD OF COAL FROM SOUTHERN EDGE INC. NO. 2 MINE WHEN APPROX. 2.25 MILES FROM THE LOADING AREA THE DRIVER FOR UNKNOWN REASONS RAN OFF THE HAUL ROAD. HE WAS THROWN FROM HIS TRUCK AND FATALLY INJURED.
Mine No 2: 1 recorded fatality Coal
MSHA record for Mine No 2 (mine ID 4608362). Fatalities, non-fatal incidents grouped by year, current operator and controller, and mine context.
Watch this mine
Email me when a new MSHA incident is filed at Mine No 2.
- Fatalities
- 1
- Total incidents
- 14
- Years on record
- 1994–1998
- Latest incident
- May 1998
- Southern Edge Inc 1993 to 1995
- Southern Edge Inc 1995 to present
Mine No 2 sits in McDowell County, West Virginia, where the Census mining category is 13.0% of county employment.
ⓘ
County figures come from the US Census Bureau's American Community Survey, 5-year pooled estimates, so the 2023 vintage covers 2019 through 2023. The Census category is 'mining, quarrying, and oil and gas extraction', which is broader than MSHA jurisdiction and includes oil and gas workers no mine employs. These figures describe the surrounding county, not this mine, and are not a factor in any specific incident.Fatalities at this mine
1 recordedReportable incidents
13 on file (excluding fatalities above)1998 · 2 incidents
BAD TOP AND WATER.
CONTINUE OF OLD FALL
1997 · 1 incident
20X20 6' HIGH #4 BELT ENTRY
1996 · 3 incidents
GLICK & SEILO HORSE BACK FELL FROM #3 ENTRY TO #4 ENTRY IN CROSS BREAK. 4' H 8' WIDE
PIECE OF DRAW ROCK FELL AND WHEN HE MOVED TWISTED HIS RIGH KNEE.
PUTTING IN BELT STRUCTURE AND CAUGHT THUMB ON STRUCTURE.
1995 · 1 incident
ROOF FALL INTERSECTION #4 HDG. 2 LEFT SECTION 400 FT INBY MAINS - 1 BREAK OUTBY FACE - APPROX 40FT LONG X 10-11 FT HIGH X 25 FT WIDE. INTERSECTION WAS SPOT BOLTED WITH 7 FT. RESIN BOLTS - TIMB ER DOWN.
1994 · 6 incidents
ROOF FALL #2 HDG. LOB - 300 FT INBY MAINS APPROX 8-9 FT X 2-3 FT HIGH X 22 FT LONG, 18 FT WIDE.2 LEFT SECTION.
INTERSECTION FELL 1 BRK INBY SPAD #73 LOB AT FACE. MEASURED 5-6 HIGH ABOVE 45" ANCHORAGE POINT. #4 HDG IS 18' 6" WIDE 3-4 BRK-18'WIDE.
INJURED WAS REACHING TO INSTALLED BELT CLAMP PREPARING TO MAKE SPLICE ON BELT WHEN HE TRIPPED ON CABLE THEREFORE TWISTING HIS LEFT KNEE.
ROOF FALL #5 ENTRY, 1 LEFT SECTION--FACE AREA 1 BRK. INBY SPAD #74. 5-6' HIGH 16-17' WIDE X 20'LONG.
ROOF FALL FACE AREA 2 HEADING FALL IS APPROX. 28 FT WIDE 18 FT LONG 0-18 FT HIGH.
OPERAT OR REPOSITIONING ROOF BOLTER ROM CENTER VALUE CHEST RELEASED TRS & RAISED FRONT BOOM CATCHING LEFT HAND ON PIVOT POINT OF MAIN FRAME & FRONT BOOM EMPLOYEE DID NOT REPORT INJURY TIME OF ACCIDENT