INJ SPOOLING CABLE BROUGHT FROM INSIDE MINE,ONTO A LARGE WOODEN SPOOL.WHILE SPOOL WAS BEING TUYRNED,INJ CAME INTO CONTACT WITH IT WITH RIGHT FOIREARM.
No 13: 8 reportable incidents Coal
MSHA record for No 13 (mine ID 3304098). Fatalities, non-fatal incidents grouped by year, current operator and controller, and mine context.
Watch this mine
Email me when a new MSHA incident is filed at No 13.
- Fatalities
- 0
- Total incidents
- 8
- Years on record
- 1990–1991
- Latest incident
- Aug 1991
- Johnson Mining Company 1987 to 1989
- Little Creek Mining Inc 1988 to 1989
- M & M Coal Company 1989 to 1989
- P & G Mining 1989 to 1990
- Beaver Creek Mining Inc 1990 to 1990
- Mountain Spring Coal Company 1990 to present
No 13 sits in Columbiana County, Ohio, where the Census mining category is 0.7% of county employment.
ⓘ
County figures come from the US Census Bureau's American Community Survey, 5-year pooled estimates, so the 2023 vintage covers 2019 through 2023. The Census category is 'mining, quarrying, and oil and gas extraction', which is broader than MSHA jurisdiction and includes oil and gas workers no mine employs. These figures describe the surrounding county, not this mine, and are not a factor in any specific incident.Reportable incidents
8 on file1991 · 5 incidents
SEPARATION OF SLATE FROM MAIN ROOF SANDSTONE ABOVE THE BOLT ANCHORAGE AND TEST HOLES. THIS EVIDENTLY A FAULT AREA. FALL WAS 30 FT LONG BY 24 FT WIDE BY 8 FT THICK IN BELT ENTRY. 50 FT INBY T AIL PIECE. FALL WAS IN 1 NORTH SECTION 1+100, #2 CROSSCUT, #3 ENTRY BELT ENTRY.
INJURED WAS INSTALLING ROOF BOLTS AND HAND WAS CAUGHT BETWEEN DRILL HEAD AND ROOF.
FALL IN 5 ENTT 35'L 18 TO 24; W 7' TO 9' THICK ON FLETCHER ROOF BOLTER
INJURED WAS IN PROCESS OF DISASSEMBLING A 2" INTAKE FRESH WATER LINE THAT WAS HANGING ACROSS INTERSECTION BOWED DOWNWARD AND LAYING ON MINE FLOOR. INJURED WAS STOOPED OVER THE LINE IN PROCESS OF REMOVING COUPLER. WHEN COUPLER RELEASED, THE END OF WATER LINE THAT WAS BOWED FLEW UPWARD STRIKING INJURED'S LEFT LEG.
1990 · 3 incidents
FALL OCCURRED AT #1 ENTRY OF NORTH MAINS BETWEEN #4 & #5 CROSS CUT. FALL APPROXIMATELY 16'X12' X5' THICK.
FALL HAPPENED AT #5 ENTRRY (FACE #6 CROSSCUT FALL POSSIBLY 10FT THICK FALL BROKE OFF FLUSH WITH CORNERS & THE ACTUAL THICKNESS CAN NOT BE DETERMINED
FALL OCCURRED 2 BREAKS OUTBY BEGINNING AT 2 WEST SECTION-INTAKE-LAST OPEN CROSS CUT OF #2 ENTRY.NORTH MAINS-THE FALL WAS 20 FT WIDE BY 35FT LONGX5FT THICK.FALL WAS ABOVE ANCHORAGE AND OCCURRED IN A FAULT AREA.