THE VICTIM WAS FOUND LYING OVER A 7200 VOLT AC HIGH-VOLTAGE SPLICE BOX ON THE 007 MMU. THE SPLICE BOX WAS LOCATED IMMEDIATELY OUTBY TEH SECTION POWER CENTER AND IS APPROX. 3 FT LONG, 2 1/2 FT WIDE AND 18 INCHES DEEP. WHEN THE VICTIM CAME IN CONTACT WITH THE HIGH VOLTAGE, IT CAUSED THE POWER TO DEENERGIZE ON TEH MINE SURFACE.
Fox Mining Corp operator
Controlled by
Charles E Yates
MSHA operator ID: P22902
Top causes
- ELECTRICAL 1 fatality
- HANDLING OF MATERIALS 31 non-fatal
- POWERED HAULAGE 21 non-fatal
- MACHINERY 17 non-fatal
- FALL OF ROOF OR BACK 8 non-fatal
- HANDTOOLS (NONPOWERED) 5 non-fatal
Incident timeline
1998
13
1997
26 (1f)
1996
24
1995
28
1994
2
Mines on record
Fatalities under this operator
1 recorded
December 21, 1997
KY · Coal
maintenance man, mechanic, repair/serviceman, boilermaker, fueler, tire tech, field service tech
Fatality · ELECTRICAL
Fox Mining Corp · Contact with electrical current