WAS SHOVEING BOLT INTO HOLE CAUGHT FINGER BETWEEN BOLT AND MACHINE HEAD WHEN BOLT BENT WHILE PUSHING.
Birds Creek Coal
MSHA record for Birds Creek (mine ID 4607277). Fatalities, non-fatal incidents grouped by year, current operator and controller, and mine context.
Watch this mine
Email me when a new MSHA incident is filed at Birds Creek.
- Fatalities
- 0
- Total incidents
- 17
- Years on record
- 1987–1993
- Latest incident
- Apr 1993
Reportable incidents
17 on file1993 · 4 incidents
SLIPS IN ROCK ALONG RIGHT SIDE OF ENTRY AT 5FT
ROOF FALL IN #3 ENTRY INTERSECITON AT FACE.
SCOOP OPERATOR CUT CORNER TO CLOSE AN DIMPACTED SHOULDER INTO RIB.
1992 · 5 incidents
SLIPPED ON SLICK PAVEMENT.
WHILE BOLTING #2 FACE A PIECE OF ROCK APPROX 2 FT LONG 18 INCHES WIDE AND 3 INCHES THICK FELL STRIKING THE BOLTER OPERATOR ON LEFT ANKLE.
FACE OF 4 ENTRY WAS NOT BOLTED THE SANDSTONE ROLLED DOWN TO WITHIN 7 FT OF THE COAL SEAM THE SHALE PASTED FROM THE SANDSTONE.
IRREGULARITIES IN ROOF STRATA.
PUSHING ROOF BOLT INTO HOLE STRAINED BACK.
1991 · 4 incidents
WHILE REMOVING A SLAB OF ROCK & COAL FROM MINER BY HAND EMPLOYEE LEFT HAND ON TOP OF ROCK CAUSING THE LEFT THUMB TO GET CAUGHT BETWEEN ROOF & ROCK
WHILE WALKING BY BOLTER OPERATORS RIGHT KNEE BUMPED RIGHT CASE STICKING OUT CAUSING A BRUISED LIGMANET ON RIGHT KNEE.
ROOF FALL #2 MAIN BELT #3 INTERSECTION NO MEN WERE PRSENT NO INJURIES OCCURRED. WILD COAL SEAM & SLIP 3' ABOVE 5' ANCHORAGE WAS CAUSE OF FALL. FLETCHER BOLTER INBY FALL MAY OR MAY NOT BE DAMAM GED.
UNSECURED STEP LADDER TO TEMP GENERATOR.
1987 · 4 incidents
A ROOF FALL OCC6RRED IN THE FACE OF #3 ENTRY AND INCLUDED THE INTERSECTION OF THE X-CUT TO #4 LOOAFED 20 FEET INBY STATION #20 THE FALL WAS 24 FEET WIDE AT TIS WIDEST POINT AND 29 FEET IN LENG TH AND WAS 5 FE9T ABOVE THE COAL SEAM.
A ROOF FALL OCC6RED ON A IDLE PERIOD BETWEEN 300PM ON 07/31/87 AND 5:00 AM ON 08/03/87.THE FALL ISLOCATED IN THE #4 ENTRY 70' ABOVE THE COAL DEASEAM.
A FALL OCCURRED3ON A IDLE PERIOD BETWEEN 300 PM 7/25 AND 500 AM ON 7-27-87 IN THE X CUT 3 TO 4 ENTRY 70 FT INBY STATION 2 IN 3 ENTRY THE FALL WAS 15 FT WIDE 54FT LONG AND TAPERED FROM COAL HEI GHT TO 11 FT. 3
A ROOF FALL OCC6RED ABOVE THE ROOF BOLT ANCORAGE IN THE X CUT BETWEEN #1 & #2 ENTRY AT THE FACE.THE FALL WAS 15' LONG 14'WIDE & 6' HIGH.